Is the OPUS prewired for DC:DC charging?
Official wiring procedure for adding vehicle-to-trailer DC-DC charging on all Opus models
Overview Opus campers do not include a DC-DC charger as standard equipment. The factory 7-pin connection provides only a maintenance trickle (typically <8 A) from the tow vehicle alternator – insufficient for meaningful charging while towing. All current Opus models are pre-wired at the factory with dedicated 6 AWG positive (red) and negative (black) runs from the 7-pin junction box to the battery compartment, making DC-DC charger installation plug-and-play on the trailer side.
Recommended Component Redarc BCDC1240D 40 A DC-DC charger (supports lead-acid, AGM, gel, and lithium profiles)
Key Benefits
- Full 40 A charging while driving
- Proper multi-stage algorithm
- Solar input ready
- Ignition trigger protects vehicle start battery
Trailer-Side Wiring (Opus – already complete from factory)
- 6 AWG red → Charge positive
- 6 AWG black → Charge negative
- Orange wire → Ignition trigger (switched 12 V)
- Green wire → Ground reference
Installation Steps – Trailer Side
- Mount Redarc BCDC1240D in battery compartment using supplied bracket.
- Connect factory red 6 AWG to charger BATTERY + terminal.
- Connect factory black 6 AWG to charger BATTERY – terminal.
- Connect orange ignition wire to charger blue IGN terminal.
- Connect green ground-reference wire to chassis ground stud.
- Set profile rotary switch per your battery type (refer to Redarc label).
Tow-Vehicle Wiring (must be added by owner or professional)
- Run 6 AWG red from vehicle battery + through 50 A midi fuse to pin 4 (or pin 10 on 13-pin) of trailer connector.
- Run 6 AWG black from vehicle battery – to pin 3 (ground).
- Run 16–18 AWG orange ignition trigger (switched 12 V) to Redarc blue wire via Anderson connector.
Fuse Protection
- Vehicle side: 50 A midi fuse within 18" of start battery
- Trailer side: Factory 50 A mega fuse already installed near battery
Torque Specifications
- All 6 AWG ring terminals: 9–11 Nm
- Redarc mounting screws: 5 Nm
Testing After Installation Ignition ON → Redarc LED should illuminate → 40 A charging within 60 seconds of engine running.
Support Contacts Redarc USA technical support: 704-247-5150 (highly responsive for wiring confirmation)
Meta Description Add 40 A DC-DC charging to any Opus camper using Redarc BCDC1240D. Factory pre-wired trailer side, exact vehicle wiring diagram, fuse locations, and torque specs included.